442 resultados para Tanque séptico


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta pesquisa apresenta o estudo comparativo de reatores anaeróbio de fluxo ascendente e manta de lodo (UASB) e tanque séptico (TS), a fim de investigar a utilização destes reatores em escala unifamiliar no tratamento de esgotos domiciliares. A pesquisa foi realizada em comunidade quilombola próxima a cidade de Belém- PA. Para isto, foram utilizados oito reatores UASB (em forma de “Y”.) e um tanque séptico prismático de câmara única. Os reatores UASB possuíam volume de 0,42 m3, enquanto que o tanque séptico volume de 4,20 m3. Cada reator foi instalado em um domicilio, sendo alimentados exclusivamente por esgoto negro (água, fezes e urina) oriundo dos vasos sanitários dos banheiros. Foi analisada a viabilidade técnica da utilização do primeiro em substituição ao segundo, tendo em vista que o TS é amplamente utilizado em locais do Brasil desprovidos de redes coletoras de esgoto. As operações foram realizadas simultaneamente durante aproximadamente 90 semanas, sendo monitorados parâmetros que possibilitaram a análise da estabilidade operacional e do desempenho de cada reator. Ao final da pesquisa foi observado que os reatores UASB apresentaram desempenho tão satisfatório ou melhor que o do TS no tratamento da matéria orgânica e de sólidos em suspensão. Com isso, ficou evidenciada a viabilidade da aplicação do reator UASB utilizado no tratamento unifamiliar de esgotos de pequenas comunidades rurais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A concentração demográfica e de sistemas coletivos de esgotamento sanitário dentro do perímetro urbano da maioria dos municípios brasileiros, dificulta a viabilização do fornecimento de serviços de tratamento de esgotos domésticos à habitações e núcleos habitacionais isolados situados em áreas periurbanas e rurais, intensificando os danos provocados pela poluição de origem antrópica ao meio ambiente e à preservação da saúde pública. Para contribuir no equacionamento deste problema, o presente estudo teve por finalidade avaliar uma wetland construída híbrida em escala real, composta por uma unidade com fluxo contínuo subsuperficial vertical seguida por uma unidade de fluxo contínuo subsuperficial horizontal, cultivadas com capim Vetiver, para o tratamento de efluente proveniente de tanque séptico. A presente configuração experimental busca uma solução de baixo custo e simplificada para o tratamento descentralizado de esgotos domésticos. A estação experimental de tratamento de esgotos, parte integrante e um dos produtos da Rede Nacional de Tratamento de Esgotos Descentralizados RENTED, foi construída no Centro Tecnológico de Hidráulica CTH / Escola Politécnica EPUSP, campus Butantã da USP, em São Paulo. O esgoto bruto foi proveniente do Conjunto Residencial da USP e do restaurante central da Cidade Universitária. As vazões média e máxima de esgoto bruto, respectivamente, de 640L.d-1 e 1600L.d-1, foram aplicadas à entrada do TS de 5.000L e deste escoaram por gravidade à entrada da wetland construída híbrida, com TDH total de 2,8d e 1,1d, respectivamente, sob aplicação das vazões média e máxima de projeto. O monitoramento do experimento em campo, incluindo o período inicial de partida, durou 6 meses consecutivos. Foram avaliados os parâmetros físico-químicos e microbiológicos do esgoto bruto e do efluente do tanque séptico e das câmaras da wetland construída híbrida durante 97 dias consecutivos. Os resultados indicaram que tanto as mudas jovens quanto as adultas de capim Vetiver adaptaram-se bem às condições ambientais. As eficiências médias de remoção no efluente tratado final quanto à matéria orgânica carbonácea foram de 96 por cento para DBO5,20 e 90 por cento para DQO, 40 por cento para N-total, 23 por cento para N-amoniacal total, 60 por cento para P-total, 52 por cento para P-PO4, 74 por cento para SST, 96 por cento para SSV, 75 por cento para sólidos sedimentáveis, 44 por cento para SDV, 88 por cento para sulfeto total, e 97 por cento para óleos e graxas totais, variando entre 73 por cento a 100 por cento . Cerca de 80 por cento da fração orgânica da matéria nitrogenada presente no esgoto bruto foi removida. A remoção de coliformes termotolerantes foi, em média, de 2 e 3 unidades log, e de Escherichia Coli, média de 1 e 3 unidades log, respectivamente, sob aplicação das vazões máxima e média, Giardia sp, média de 99,995 por cento , Cryptosporidium sp, média de 98,7 por cento , Enterovírus, média de 99,6 por cento , e Ascaris sp, média de 0,10 ovo/L. A remoção de sulfetos propiciou a geração de efluente tratado sem odores desagradáveis. A diminuição da vazão aplicada e a elevação do TDH influenciaram positivamente no desempenho do sistema com relação às remoções dos parâmetros físico-químicos e microbiológicos. Com base no presente estudo, ficou evidente o benefício da associação de wetlands construídas com fluxo vertical e horizontal no tratamento de efluente de tanque séptico. O capim Vetiver apresentou bom potencial de utilização em wetlands 8 construídas para tratamento de esgotos domésticos. O sistema experimental de tratamento apresentou flexibilidade operacional, mantendo bom desempenho inclusive nos períodos de sobrecarga. A qualidade do efluente tratado final obtido no presente estudo atende às exigências de lançamento e aos padrões de emissão de efluentes líquidos em corpos dágua e em sistemas públicos de esgotamento sanitário definidos na legislação ambiental federal e do Estado de São Paulo. A tecnologia de wetlands construídas híbridas associada ao tratamento de efluentes de tanque séptico apresentou bom potencial para o tratamento descentralizado de esgotos domésticos, inclusive em regiões com pouca disponibilidade de área livre.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A validação de limpeza de equipamentos é requisito regulatório para assegurar que os procedimentos de limpeza removem os resíduos de produto e agente de limpeza existentes até um nível de aceitação pré-determinado, garantindo que não haja contaminação cruzada. A metodologia analítica escolhida para monitorar a ocorrência de contaminação cruzada foi a determinação de carbono orgânico total (TOC) por ser uma técnica não específica permitindo assim quantificar os resíduos antes e após o procedimento de limpeza. Para execução desta validação foi selecionado o pior caso em relação ao contaminante. A vacina Hib foi escolhida como pior caso, pois possui maior aderência ao aço inox 316L, apresentando uma menor percentagem de recuperação, quando comparada à vacina Meningite A e C, sendo respectivamente de 93,0% e 98,4% para o tempo de extração de 30 segundos e 67,8% e 72,6% para o tempo de extração de 10 segundos. O resíduo aceitável de produto em água de rinsagem foi de 0,0007 g/mL de polissacarídeo (0,49 g/mL de TOC) e em swab foi de 0,006 g/mL de polissacarídeo (3,49 g/mL de TOC). As amostras retiradas para determinação de resíduo de produto foram analisadas e corrigidas pelo fator de recuperação deste resíduo para amostras de água de rinsagem que é de 98,5% e para amostras em swab que é de 98,4%. Já o resíduo aceitável para agente de limpeza (NaOH) foi de 3,5 g/mL que fornece um pH de 9,94, porém não existem evidências que a concentração calculada de resíduo de NaOH não interferirá quimicamente ao entrar em contato com a vacina. Assim o critério adotado foi o mesmo da água para injetáveis, segundo USP que é pH entre 5 e 7. As amostras retiradas para determinação de resíduo de agente de limpeza não foram corrigidas pelo fator de recuperação uma vez que o critério utilizado é muito mais crítico que o calculado. Todas as análises realizadas apresentaram resultados dentro dos parâmetros aceitáveis permitindo a conclusão de que o procedimento de limpeza para tanque de aço inox 316L é eficiente removendo os resíduos até níveis aceitáveis, evitando assim uma contaminação cruzada

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ao longo dos últimos anos, apesar de todo desenvolvimento e pesquisa, a mortalidade na sepse permanece elevada. Na área de microcirculação foram realizados estudos em modelos experimentais de sepse ao longo das últimas duas décadas, quando se observou, através de técnicas invasivas, alterações como redução expressiva da densidade capilar funcional. A técnica denominada sidestream dark field (SDF) imaging, recentemente desenvolvida, permite a avaliação da microcirculação de forma transcutânea. A utilização desta técnica permitiu evidenciar a redução da densidade capilar funcional em pacientes com sepse grave quando comparado a um indivíduo saudável. Posteriormente, foi demonstrado que alterações persistentes na microcirculação de pacientes sépticos, mesmo com sinais vitais estabilizados, estão associadas com pior prognóstico.Evidentemente, os pacientes com sepse grave ou choque séptico sofrem uma grande quantidade de intervenções terapêuticas, aonde muitas delas alteram a microcirculação. Estudos analisando a microcirculação em pacientes em uso de nitroglicerina, corticóide, recebendo hemotransfusão ou ainda infusão de noradrenalina foram publicados recentemente.Entretanto, até o presente momento, não existem publicações que descrevam a influência dos sedativos na microcirculação de pacientes com choque séptico. As drogas mais comumente utilizadas para sedação de pacientes em ventilação mecânica são o sedativo midazolam e o anestésico propofol. Os objetivos do estudo foram: avaliar o efeito dos principais agentes sedativos utilizados na prática clínica na microcirculação de pacientes com choque séptico utilizando a técnica de sidestream dark field imaging, comparar os efeitos na microcirculação do midazolam com o propofol em pacientes com choque séptico e verificar se existe relação das alterações microcirculatórias provocadas pelos sedativos com as variações de diferentes parâmetros hemodinâmicos, gasométricos ou metabólicos como pressão arterial, índice cardíaco, lactato e saturação venosa central de oxigênio. Foram estudados (estudo prospectivo) 16 pacientes internados no Centro de Terapia Intensiva da Casa de Saúde São José. Os pacientes internados com diagnóstico de choque séptico e que possuíam indicação clínica de ventilação mecânica e de suspensão diária da sedação foram submetidos ao estudo da microcirculação na mucosa sublingual utilizando a técnica de sidestream dark field imaging. Estes pacientes foram sedados conforme orientação do protocolo já existente de sedação, inicialmente com propofol e posteriormente com midazolam. Os principais resultados observados foram:a macrohemodinâmica não diferiu nos 2 momentos do exame, o BIS (bispectral índex of sedation) se manteve na faixa recomendada nos 2 momentos do exame, tendo aumentado quando o paciente acordava, conforme esperado, e a proporção de vasos pequenos perfundidos e o índice de fluxo da microcirculação foram significativamente menores, enquanto o índice de heterogeneidade foi significativamente maior quando os pacientes estavam recebendo infusão de propofol quando comparados com a infusão de midazolam. Concluímos que, em pacientes com choque séptico, a administração de midazolam resulta em uma melhora dos parâmetros microcirculatórios quando comparada com a administração de propofol. Essa diferença não pode ser atribuída a alterações de variáveis hemodinâmicas sistêmicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Choque séptico é caracterizado por desequilíbrio entre o transporte e o consumo de oxigênio, podendo acarretar hipóxia tecidual. A disfunção microcirculatória, característica cardinal da fisiopatologia do choque séptico, causa má distribuição de fluxo sanguíneo microvascular e, consequentemente, shunt de oxigênio, disóxia tissular e, teoricamente, diminuição no consumo de oxigênio (VO2) pela célula. No presente estudo, foi investigada a associação entre alterações microcirculatórias causadas pela sepse e o consumo de oxigênio em pacientes pediátricos. Dezessete crianças com choque séptico ressuscitadas foram estudadas em quatro momentos durante a internação na unidade de terapia intensiva (dentro de 24, 48 e 72 horas após a admissão ou diagnóstico de choque e após a resolução deste, antes da extubação traqueal). A microcirculação sublingual foi avaliada utilizando o método de imagem Sidestream dark field (SDF) e o VO2 foi calculado através da calorimetria indireta. Outras variáveis hemodinâmicas, como transporte de oxigênio, índice cardíaco, pressão arterial invasiva, lactato arterial e saturação venosa central, foram coletadas. Embora as variáveis hemodinâmicas tenham se mantido em níveis satisfatórios, graves alterações na microcirculação foram visualizadas, especialmente na densidade de vasos pequenos perfundidos (DVPP), na proporção de vasos pequenos perfundidos (PVPP) e no índice de fluxo microvascular (MFI). Foram encontradas assosciações significativas entre o VO2 e os parâmetros da microcirculação: dVO2 e dDVPP (β coefficient= 6,875; p<0,001), dVO2 e dPVPP (β coefficient=92,246; p<0,001) e dVO2 e dMFI (β coefficient=21,213; p<0,001). Não foram encontradas correlações entre as alterações microcirculatórias e as outras variáveis. Em conclusão, este estudo mostrou que pacientes pediátricos com choque séptico apresentaram grave disfunção microvascular e que o fluxo microcirculatório alterado estava associado ao VO2, podendo estar implicado na fisiopatologia da disóxia tecidual da sepse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Ciências Farmacêuticas, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015